GenPat Platform, Wiki

Topics
Topics

2AS_hybrid

Introduction

2AS_hybrid analysis performs the hybrid assembly of short and long reads. Hybrid assembly grants the coverage of repetitive DNA regions and place them in the correct positions, thanks to third-generation sequencing technologies that produce long reads; at the same time, hybrid assembly increases accuracy, thanks to the use of second-generation sequencing technologies that produce short reads.

uml diagram

Run 2AS_hybrid analysis

Once the analysis 2AS_hybrid has been selected in the dedicated run analyses page, it will be possible to choose the bioinformatics software ("method") to use, among those available for the analysis. The only tool that can be used for this analysis is:

  • Unicycler - hybrid assembly pipeline for bacterial genomes.

Unicycler GitHub Page: https://github.com/rrwick/Unicycler

2AS_hybrid requires 2 inputs (please, refer to the image below):

  1. Long reads from nanopore-based sequencers ("Long reads" field is mandatory);
  2. Short reads from Illumina sequencers ("Input selection" field is mandatory). Possible short read inputs can be obtained from pre-processing analyses of the reads, such as:

Note: the execution of the hybrid assembly will fail if long reads are used, as the second input, instead of Illumina short reads.

The input selection interface provides the advanced input selection mode, to allow the use of inputs processed by different methods that were applied upstream in the analysis workflow.

Once the analysis is launched, the page generates a link to the Check analysis section to allow a check of the processus status. The system will send the user a notification both when the analysis is successfully started and when the operation is completed.

Result folder

To consult the guide on how to download files from the platform, please refer to the dedicated page.

The Result folder can be browsed by clicking the link available within the analysis card, in the Result data section. Inside the subsequent results folder, there are 3 subfolders:

  • meta: (metadata), where the log and configuration files of the executed process are saved;
  • qc: (quality check) where check quality files are saved. It also contains the two sub-folders meta and result. For this analysis, quality check is performed with quast;
  • result: where the files containing the results produced by the analysis are saved.

The table below contains a list of files present in the folders, along with some useful information.

File Description Location
DSXXXXXXXX-DTXXXXXX_ID_unicycler.gfa assembly in .gfa format folder: result
DSXXXXXXXX-DTXXXXXX_ID_unicycler_assembly.fasta hybrid assembly file in fasta format folder: result
DSXXXXXXXX-DTXXXXXX_ID_quast.csv quality statistics file of the assembly folder: qc > result